DPC31 HW
SchnittStellenCenter
DPC31 HW Description
Version V1.0 Page 77
Copyright (C) Siemens AG 2000. All rights reserved. 12/00
No. Parameters Min Max Unit
60
Address setup time to AS ↓
0ns
61
AS ↓ to Data valid (access to RAM)
4T + 27 ns
AS ↓ to Data valid (access to the registers)
4T + 27 ns
62
Address (AB
12..0
) hold time after AS ↑
10 ns
63
R_W ↓ setup time to AS ↓
10 ns
64 AS Pulse Width
6T − 10
ns
65
Data hold time after AS ↑
38ns
66 AS inactive time 10 ns
67
R_W hold time after AS ↑
10 ns
68
XCS ↓ setup time to AS ↓
-5 ns
69
XCS hold time after AS ↑
0ns
70
AS ↓ to XDSACK ↓ (standard Ready)
5T + 25 ns
71
AS ↓ to XDSACK ↓ (early Ready)
4T + 25 ns
72
XDSACK hold time after AS ↑
425ns
73 AS cycle time 6T ns
74
Data setup time to AS ↑
10 ns
75
Data hold time after AS ↑
10 ns
76 AS Pulse Width 4T ns
77
last AS ↓ (Read) to XCS ↓
4T+10 ns
78
XCS ↑ to next AS ↑ (Write)
4T ns
79 AS to next AS (Write, XCS don’t care) 6T ns
Table 9.6-9: Timing Values for the Asynchronous Motorola Mode
AS
VALID
Data Out
AB(12..0)
DB(7..0)
R_W
E_Clock = log.'0'
63
70
62
65
61
64
XDSACK
(normal)
XDSACK
(early)
67
72
60
71
66
73
69
XCS
6877
Figure 9.6-10: Asynchronous Motorola Mode, Processor Read Timing