DPC31 HW
SchnittStellenCenter
DPC31 HW Description
Version V1.0 Page 33
Copyright (C) Siemens AG 2000. All rights reserved. 12/00
buffer, the display ‘U_Buffer_Cleared’ is set with ‘User_New_Dout command’ (refer to Table 5.2-8) and the
user receives the information that it is cleared data (substitute values).
5.2.7 Read_Inputs (SAP56)
The Read_Input message is accepted by the MAC only with request data length = 0, in the mode
‘Data_Exchange’, from any master. For this, DPS enters the corresponding validation values in ‘SAP56 of
the SAP_SCB’. In the other modes, the DPC31 responds with ‘no service activated’ (modes ‘Wait_Prm,
Wait_Cfg’) or ‘no resource’ (request data length # 0).
The exchange of the Read_Input buffer has been described previously. Between the initial call and the
repetition if there is a buffer change from ‘U’ -> ‘N’ -> ‘D’ (through User_New_Din command), the new input
data is sent at the repetition.
5.2.8 Read_Outputs (SAP57)
The Read_Output message is accepted by the MAC only with request data length = 0, in the mode
‘Data_Exchange’, from any master. For this, DPS enters the corresponding validation values in ‘SAP57 of
the SAP_SCB’. In the other modes, the DPC31 responds with ‘no service activated/no resource’.
The exchange of the Read_Output buffer has been described previously.
Between the initial call and the repetition if there is a buffer change from ‘N’ -> ‘U’ (through User_New_Dout
command), the new output data is sent at the repetition.
5.2.9 Get_Config (SAP59)
The Get_Config message is accepted in all modes. If the call message contains request data, the MAC
acknowledges with ‘no resource’.