Siemens SIMATIC Distributed I/O System DP/ASi Link Specifiche

Navigare online o scaricare Specifiche per Bridge e ripetitori Siemens SIMATIC Distributed I/O System DP/ASi Link. Siemens SIMATIC Distributed I/O System DP/ASi Link Specifications Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 240
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Preface, Contents
Product Overview
1
Getting Started
2
Configuration Options with the
ET 200M
3
Installation
4
Wiring
5
Commissioning and Diagnostics
6
Maintenance
7
Technical Specifications
8
Compatibility Between the
IM 153-x Modules
9
Appendix
Order Numbers for the ET 200M
A
Glossary, Index
Edition 10/2002
EWA-4NEB780600602-06
Distributed I/O Device
ET 200M
Manual
SIMATIC
This manual is part of the
documentation package
6ES7153-1AA00-8BA0
The following supplement is part of this documentation:
No. Designation
Drawing number
Edition
1 Product information A5E000272208-01 11/2003
Vedere la pagina 0
1 2 3 4 5 6 ... 239 240

Sommario

Pagina 1 - Drawing number

Preface, ContentsProduct Overview1Getting Started2Configuration Options with theET 200M3Installation4Wiring5Commissioning and Diagnostics6Maintenance7

Pagina 2 - Safety Guidelines

ContentsxDistributed I/O Device ET 200MEWA-4NEB780600602-063.7 Clock Synchronism 3-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 3 - with the

Wiring5-14Distributed I/O Device ET 200MEWA-4NEB780600602-06Table 5-3 Wiring rules for module front connectors Wiring Rules for ... Module Front Conne

Pagina 4

Wiring5-15Distributed I/O Device ET 200MEWA-4NEB780600602-065.2.2 Wiring the Power Supply and IM 153-xPower CablesTo wire the power supply, use flexib

Pagina 5

Wiring5-16Distributed I/O Device ET 200MEWA-4NEB780600602-06Wiring with the JumperTo wire the power supply module and IM 153-x, proceed as follows (se

Pagina 6 - Additional Support

Wiring5-17Distributed I/O Device ET 200MEWA-4NEB780600602-065.2.3 Wiring the Front Connectors of the Signal ModulesS7 Explosion-Proof ModulesYou can f

Pagina 7 - A&D Technical Support

Wiring5-18Distributed I/O Device ET 200MEWA-4NEB780600602-06Preparing the Connector for WiringTo prepare for wiring, proceed as follows:!WarningAccide

Pagina 8

Wiring5-19Distributed I/O Device ET 200MEWA-4NEB780600602-06Wiring the Front ConnectorTable 5-4 Wiring the front connector Step 20-Pin Front Connecto

Pagina 9 - Contents

Wiring5-20Distributed I/O Device ET 200MEWA-4NEB780600602-06Preparing the Signal Module for OperationTable 5-5 Preparing the signal module for operati

Pagina 10 - EWA-4NEB780600602-06

Wiring5-21Distributed I/O Device ET 200MEWA-4NEB780600602-065.2.4 Connecting Shielded Cables via a Shield Contact ElementIntroductionThis section tell

Pagina 11

Wiring5-22Distributed I/O Device ET 200MEWA-4NEB780600602-06Installing the Shield Contact ElementInstall the shield contact element as follows:1. Push

Pagina 12

6-1Distributed I/O Device ET 200MEWA-4NEB780600602-06Commissioning and DiagnosticsChapter OverviewSection Subject Page6.1 Commissioning and Startup of

Pagina 13

ContentsxiDistributed I/O Device ET 200MEWA-4NEB780600602-066.4.3 Master PROFIBUS Address 6-21. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 14

Commissioning and Diagnostics6-2Distributed I/O Device ET 200MEWA-4NEB780600602-066.1.1 Prerequisites for CommissioningSoftware PrerequisitesTable 6-1

Pagina 15 - Product Overview

Commissioning and Diagnostics6-3Distributed I/O Device ET 200MEWA-4NEB780600602-06Prerequisites for CommissioningTable 6-2 Commissioning prerequisites

Pagina 16 - What Is PROFIBUS-DP?

Commissioning and Diagnostics6-4Distributed I/O Device ET 200MEWA-4NEB780600602-066.1.2 Startup of the IM 153-1Switch on the supplyvoltage for the DP

Pagina 17

Commissioning and Diagnostics6-5Distributed I/O Device ET 200MEWA-4NEB780600602-066.1.3 Startup of the IM 153-2/153-2 FOThe designation IM 153-2 in th

Pagina 18

Commissioning and Diagnostics6-6Distributed I/O Device ET 200MEWA-4NEB780600602-06Has the IM 153-2 (b) already received configuration data from the DP

Pagina 19 - ”SIMATIC S7-DP Slave”

Commissioning and Diagnostics6-7Distributed I/O Device ET 200MEWA-4NEB780600602-06Startup for Time Synchronization/Time Stamping of Signal ChangesIs t

Pagina 20

Commissioning and Diagnostics6-8Distributed I/O Device ET 200MEWA-4NEB780600602-066.1.4 PROFIBUS-DPV1 ModeThe ET 200M fulfills the requirements of DPV

Pagina 21

Commissioning and Diagnostics6-9Distributed I/O Device ET 200MEWA-4NEB780600602-06Actions Following Diagnostic Message in S7 or DPV1 ModeEvery diagnos

Pagina 22 - Features and Functions

Commissioning and Diagnostics6-10Distributed I/O Device ET 200MEWA-4NEB780600602-066.2 Diagnostics Using LEDsIM 153-1Table 6-5 Status and error LEDs o

Pagina 23

Commissioning and Diagnostics6-11Distributed I/O Device ET 200MEWA-4NEB780600602-06IM 153-2Table 6-6 Status and error messages of the IM 153-2SFBFONAC

Pagina 24

ContentsxiiDistributed I/O Device ET 200MEWA-4NEB780600602-06Figures1-1 Typical PROFIBUS-DP network structure 1-3. . . . . . . . . . . . . . . . . . .

Pagina 25

Commissioning and Diagnostics6-12Distributed I/O Device ET 200MEWA-4NEB780600602-06Table 6-6 Status and error messages of the IM 153-2SFBFONACTSF (gro

Pagina 26

Commissioning and Diagnostics6-13Distributed I/O Device ET 200MEWA-4NEB780600602-066.3 Diagnostics Using STEP 7 and STEP 5Slave DiagnosticsThe slave

Pagina 27 - Getting Started

Commissioning and Diagnostics6-14Distributed I/O Device ET 200MEWA-4NEB780600602-06Example of Displaying the S7 Diagnosis Using SFC 13 ”DPNRM_DG”Here

Pagina 28 - 2.1 Introduction

Commissioning and Diagnostics6-15Distributed I/O Device ET 200MEWA-4NEB780600602-06Example of Displaying the Slave Diagnosis with FB 192 ”IM308C”Here

Pagina 29

Commissioning and Diagnostics6-16Distributed I/O Device ET 200MEWA-4NEB780600602-066.4 Structure of the DiagnosisIntroductionThe IM 153-x makes the st

Pagina 30 - 2.4 Installation

Commissioning and Diagnostics6-17Distributed I/O Device ET 200MEWA-4NEB780600602-066.4.1 Structure of the Slave DiagnosisNotes on Enhanced DiagnosisTo

Pagina 31 - 2.5 Wiring

Commissioning and Diagnostics6-18Distributed I/O Device ET 200MEWA-4NEB780600602-06Structure of the Slave DiagnosisByte 0Byte 1Station statuses 1 to 3

Pagina 32

Commissioning and Diagnostics6-19Distributed I/O Device ET 200MEWA-4NEB780600602-066.4.2 Station Statuses 1 to 3DefinitionStation statuses 1 to 3 prov

Pagina 33

Commissioning and Diagnostics6-20Distributed I/O Device ET 200MEWA-4NEB780600602-06Table 6-8 Structure of station status 1 (Byte 0), continuedBit Caus

Pagina 34 - 2.7 Configuration

Commissioning and Diagnostics6-21Distributed I/O Device ET 200MEWA-4NEB780600602-066.4.3 Master PROFIBUS AddressDefinitionThe master PROFIBUS address

Pagina 35

ContentsxiiiDistributed I/O Device ET 200MEWA-4NEB780600602-066-9 Structure of the H status of the IM 153-2 (only for S7-400H) 6-28. . . . . . . . . .

Pagina 36 - 2.9 Switching On

Commissioning and Diagnostics6-22Distributed I/O Device ET 200MEWA-4NEB780600602-066.4.5 Module DiagnosisDefinitionThe module diagnosis indicates whet

Pagina 37 - 2.10 Diagnostics

Commissioning and Diagnostics6-23Distributed I/O Device ET 200MEWA-4NEB780600602-066.4.6 Module StatusDefinitionThe module status indicates the status

Pagina 38 - SM 322: Short Circuit to L+

Commissioning and Diagnostics6-24Distributed I/O Device ET 200MEWA-4NEB780600602-066.4.7 Channel-Specific DiagnosisDefinitionThe channel-specific diag

Pagina 39

Commissioning and Diagnostics6-25Distributed I/O Device ET 200MEWA-4NEB780600602-067Bit no.10654 132000001B to 001010B: ID number of the module that d

Pagina 40

Commissioning and Diagnostics6-26Distributed I/O Device ET 200MEWA-4NEB780600602-06Channel-Specific Error MessagesTable 6-12 Channel-specific error me

Pagina 41

Commissioning and Diagnostics6-27Distributed I/O Device ET 200MEWA-4NEB780600602-06Table 6-13 Channel-specific error messages – manufacturer-specificE

Pagina 42

Commissioning and Diagnostics6-28Distributed I/O Device ET 200MEWA-4NEB780600602-066.4.8 H Status (with S7-400H and Standard Redundancy Only)The IM 15

Pagina 43 - Operating Principle

Commissioning and Diagnostics6-29Distributed I/O Device ET 200MEWA-4NEB780600602-066.4.9 InterruptsDefinitionThe interrupts section of the slave diagn

Pagina 44 - Principle

Commissioning and Diagnostics6-30Distributed I/O Device ET 200MEWA-4NEB780600602-06Removal and Insertion InterruptsTo remove and insert modules during

Pagina 45 - In the Redundant System

Commissioning and Diagnostics6-31Distributed I/O Device ET 200MEWA-4NEB780600602-06InterruptsThe interrupt section for the ET 200M is structured as fo

Pagina 46

ContentsxivDistributed I/O Device ET 200MEWA-4NEB780600602-067-2 Installing new modules 7-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 47 - Prerequisites for the ET 200M

Commissioning and Diagnostics6-32Distributed I/O Device ET 200MEWA-4NEB780600602-06Diagnostic Interrupt, Bytes x+4 to x+7Bytes x+4 to x+7 correspond t

Pagina 48 - S7-400H as DP master

Commissioning and Diagnostics6-33Distributed I/O Device ET 200MEWA-4NEB780600602-06Diagnostic Interrupt of Modules with Digital InputsByte x+870H: Mod

Pagina 49 - Power Supply of the IM 153-2

Commissioning and Diagnostics6-34Distributed I/O Device ET 200MEWA-4NEB780600602-06Diagnostic Interrupt of Modules with Digital OutputsByte x+87072H:

Pagina 50

Commissioning and Diagnostics6-35Distributed I/O Device ET 200MEWA-4NEB780600602-06Diagnostic Interrupt of Modules with Analog Inputs71H: Module with

Pagina 51

Commissioning and Diagnostics6-36Distributed I/O Device ET 200MEWA-4NEB780600602-06Diagnostic Interrupt of Modules with Analog Outputs73H: Module with

Pagina 52

Commissioning and Diagnostics6-37Distributed I/O Device ET 200MEWA-4NEB780600602-06Process Interrupt of Analog Input ModulesByte x+4Upper limit violat

Pagina 53 - 3.7 Clock Synchronism

Commissioning and Diagnostics6-38Distributed I/O Device ET 200MEWA-4NEB780600602-06Module Removal/Insertion InterruptThe module ID that was removed or

Pagina 54

Commissioning and Diagnostics6-39Distributed I/O Device ET 200MEWA-4NEB780600602-06Removal/Insertion Interrupt with S7/M7-DP Master or DPV1 MasterIf y

Pagina 55

Commissioning and Diagnostics6-40Distributed I/O Device ET 200MEWA-4NEB780600602-06Interrupts with Another DP MasterIf you operate the ET 200M with an

Pagina 56

7-1Distributed I/O Device ET 200MEWA-4NEB780600602-06MaintenanceMaintenanceThe ET 200M is a maintenance-free DP slave.Chapter OverviewIn this chapter

Pagina 57

1-1Distributed I/O Device ET 200MEWA-4NEB780600602-06Product OverviewIn This ChapterThe product overview tells you: How to incorporate the ET 200M di

Pagina 58 - Time Calculation

Maintenance7-2Distributed I/O Device ET 200MEWA-4NEB780600602-06Removing the Power Supply ModuleTo remove the power supply module, proceed as follows:

Pagina 59 - Further Information

Maintenance7-3Distributed I/O Device ET 200MEWA-4NEB780600602-067.2 Replacing the IM 153-1Initial SituationThe IM 153-1 is installed. You want to inst

Pagina 60 - 3.8 Identification Data

Maintenance7-4Distributed I/O Device ET 200MEWA-4NEB780600602-06Installing a New ModuleInstall the new module as follows:1. Set the same DP address on

Pagina 61

Maintenance7-5Distributed I/O Device ET 200MEWA-4NEB780600602-06IM 153-2: Unplugging the Bus ConnectorWith a looped-through interconnecting cable you

Pagina 62

Maintenance7-6Distributed I/O Device ET 200MEWA-4NEB780600602-06In the Case of RedundancyNoteOnly replace the IM 153-2/-2 FO in a de-energized state!I

Pagina 63

Maintenance7-7Distributed I/O Device ET 200MEWA-4NEB780600602-063. Disconnect the wiring.4. Remove the fixing screws of the IM 153-2/-2 FO.5. Swing th

Pagina 64 - 3.10 Direct Communication

Maintenance7-8Distributed I/O Device ET 200MEWA-4NEB780600602-067.4 Replacing Modules without the ”Module Change DuringOperation” FunctionRemoving a M

Pagina 65 - Installation

Maintenance7-9Distributed I/O Device ET 200MEWA-4NEB780600602-06Removing the Front Connector Coding KeyPrior to installing the new module, you must re

Pagina 66 - 4.1 Mechanical Configuration

Maintenance7-10Distributed I/O Device ET 200MEWA-4NEB780600602-06Putting a New Module into ServiceTable 7-3 Putting new modules into service Step Putt

Pagina 67 - 4.1.2 Clearance Measurements

Maintenance7-11Distributed I/O Device ET 200MEWA-4NEB780600602-067.5 Replacing Modules with the ”Module Change DuringOperation” FunctionPrerequisitesY

Pagina 68 - Length of the Rails

Product Overview1-2Distributed I/O Device ET 200MEWA-4NEB780600602-06What Is PROFIBUS-DP?PROFIBUS-DP is an open bus system based on the IEC 61784-1:20

Pagina 69

Maintenance7-12Distributed I/O Device ET 200MEWA-4NEB780600602-06Removing the Front Connector Coding KeyPrior to installing the new module, you must r

Pagina 70

Maintenance7-13Distributed I/O Device ET 200MEWA-4NEB780600602-067.6 Replacing the Bus ModuleRemoving the Bus ModuleOnly remove bus modules if they ar

Pagina 71 - Installation Options

Maintenance7-14Distributed I/O Device ET 200MEWA-4NEB780600602-067.7 Changing Fuses in Digital Output ModulesFuses for Digital OutputsFuses are used f

Pagina 72 - 4.2 Installation

Maintenance7-15Distributed I/O Device ET 200MEWA-4NEB780600602-06Changing FusesThe fuses are located at the left side of the module.1. Remove the digi

Pagina 73

Maintenance7-16Distributed I/O Device ET 200MEWA-4NEB780600602-067.8 Update of the IM 153-x7.8.1 Update of the IM 153-1/-2Ax0xPlease contact your SIEM

Pagina 74 - Fixing Screws

Maintenance7-17Distributed I/O Device ET 200MEWA-4NEB780600602-06PrerequisitesFor update via PROFIBUS-DP  The IM 153-2 in the station which is to be

Pagina 75 - Installing the Rail

Maintenance7-18Distributed I/O Device ET 200MEWA-4NEB780600602-06Sample ConfigurationUpdate from the PG/PC via PROFIBUS-DP (Direct) The PG/PC with the

Pagina 76 - Accessories

Maintenance7-19Distributed I/O Device ET 200MEWA-4NEB780600602-06Update via MMC You perform an update via MMC in the following way:Table 7-8 Update vi

Pagina 77 - Sequence for Installation

Maintenance7-20Distributed I/O Device ET 200MEWA-4NEB780600602-06Update in the Redundant SystemIf the update of the active IM 153-2 is performed via P

Pagina 78 - Modules and Modules)

8-1Distributed I/O Device ET 200MEWA-4NEB780600602-06Technical SpecificationsIn This ChapterYou will find the following: The standards, certificates

Pagina 79 - 4.2.4 After Installation

Product Overview1-3Distributed I/O Device ET 200MEWA-4NEB780600602-06Structure of a PROFIBUS-DP NetworkThe figure below shows you a typical PROFIBUS-D

Pagina 80 - Applying Slot Numbers

Technical Specifications8-2Distributed I/O Device ET 200MEWA-4NEB780600602-068.1 Standards, Certificates and ApprovalsCE ApprovalThe ET 200M distribut

Pagina 81 - Connecting the Bus Connector

Technical Specifications8-3Distributed I/O Device ET 200MEWA-4NEB780600602-06UL ApprovalUnderwriters Laboratories Inc. to UL 508 (Industrial Control

Pagina 82 - Installing Connectors

Technical Specifications8-4Distributed I/O Device ET 200MEWA-4NEB780600602-06FM ApprovalFactory Mutual Research (FM) toApproval Standard Class Number

Pagina 83 - Reusing Fiber-Optic Cables

Technical Specifications8-5Distributed I/O Device ET 200MEWA-4NEB780600602-06Ship-Building ApprovalClassification organizations: ABS (American Bureau

Pagina 84

Technical Specifications8-6Distributed I/O Device ET 200MEWA-4NEB780600602-06Laser Safety Class Certification (for IM 153-2 FO)Class 1 to EN 60825-1:

Pagina 85 - Changing the PROFIBUS Address

Technical Specifications8-7Distributed I/O Device ET 200MEWA-4NEB780600602-068.2 Parameters of the IM 153-x Parameter AssignmentAssign parameters to t

Pagina 86

Technical Specifications8-8Distributed I/O Device ET 200MEWA-4NEB780600602-06Parameters for Time StampingAssign parameters for time stamping with STEP

Pagina 87 - PNO Installation Guidelines

Technical Specifications8-9Distributed I/O Device ET 200MEWA-4NEB780600602-068.3 Technical SpecificationsGeneral Technical SpecificationsIn the Module

Pagina 88 - 5.1 Electrical Configuration

Technical Specifications8-10Distributed I/O Device ET 200MEWA-4NEB780600602-06Technical Specifications IM 153-2 F0IM 153-2IM 153-1Time Synchronization

Pagina 89 - 24V DC Power Supply

Technical Specifications8-11Distributed I/O Device ET 200MEWA-4NEB780600602-06Dimensioned Drawing of the IM 153-1/-2/-2 FOYou can find a dimensioned d

Pagina 90

Product Overview1-4Distributed I/O Device ET 200MEWA-4NEB780600602-061.2 What Is the ET 200M Distributed I/O Device?DefinitionThe ET 200M distributed

Pagina 91 - Grounded Supply

Technical Specifications8-12Distributed I/O Device ET 200MEWA-4NEB780600602-068.4 Time Delay of the ET 200MResponse Time – A DefinitionThe response ti

Pagina 92 - Rule: Ground Load Circuits

Technical Specifications8-13Distributed I/O Device ET 200MEWA-4NEB780600602-06Switchover Time in the Case of RedundancyThe switchover time depends on

Pagina 93

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-068.5.1 Einsatz der ET 200M / S7-300 im explosions-gefährdeten Bereich Zone 2

Pagina 94

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-06InstandhaltungFür eine Reparatur muss die betroffene Baugruppe an den Fertig

Pagina 95 - Power Supply Units

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-068.5.2 Use of the ET 200M / S7-300 in a Zone 2Hazardous AreaZone 2Hazardous

Pagina 96 - Insulation Monitoring

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-06MaintenanceIf repair is necessary, the affected module must be sent to the p

Pagina 97

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-068.5.3 Utilisation de l'ET 200M / S7-300 dans unenvironnement à risque

Pagina 98 - SM 334; AI 4/AO 2 8/8Bit

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-06EntretienSi une réparation est nécessaire, le module concerné doit être expé

Pagina 99 - 5.2 Wiring

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-068.5.4 Aplicación de la ET 200M / S7-300 en áreas conpeligro de explosión, z

Pagina 100

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-06MantenimientoPara una reparación se ha de remitir el módulo afectado al luga

Pagina 101

Product Overview1-5Distributed I/O Device ET 200MEWA-4NEB780600602-06”SIMATIC S7-DP Slave”The ET 200M distributed I/O system is part of the SIMATIC S7

Pagina 102 - Wiring with the Jumper

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-068.5.5 Impiego dell'ET 200M / S7-300 nell'area apericolo di esplos

Pagina 103 - Spring Terminals

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-06ManutenzionePer una riparazione, l'unità interessata deve essere inviat

Pagina 104

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-068.5.6 Gebruik van de ET 200M / S7-300 in hetexplosief gebied zone 2Zone 2Ex

Pagina 105 - Wiring the Front Connector

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-06InstandhoudingVoor een reparatie moet de betreffende module naar de plaats v

Pagina 106

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-068.5.7 Brug af ET 200M / S7-300 i det eksplosionfarligeområde zone 2Zone 2Ek

Pagina 107 - Application

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-06VedligeholdelseSkal den pågældende komponent repareres, bedes De sende den t

Pagina 108 - Attaching Cables

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-068.5.8 ET 200M / S7-300:n käyttöräjähdysvaarannetuilla alueilla, vyöhyke 2Vy

Pagina 109 - Commissioning and Diagnostics

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-06KunnossapitoKorjausta varten täytyy kyseinen rakenneryhmä lähettää valmistus

Pagina 110 - Software Prerequisites

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-068.5.9 Användning av ET 200M / S7-300 iexplosionsriskområde zon 2Zon 2Explos

Pagina 111 - Commissioning the DP Slave

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-06UnderhållVid reparation måste den aktuella komponentgruppen insändas till ti

Pagina 112 - 6.1.2 Startup of the IM 153-1

Index-2Distributed I/O Device ET 200MEWA-4NEB780600602-06!Dangerindicates that death, severe personal injury or substantial property damage will resul

Pagina 113

Product Overview1-6Distributed I/O Device ET 200MEWA-4NEB780600602-06ComponentsThere are a number of components available for the setup and commission

Pagina 114

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-068.5.10 Uso do ET 200M / S7-300 em área exposta aoperigo de explosão 2Zona 2

Pagina 115

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-06ReparoOs grupos construtivos em questão devem ser remetidos para o local de

Pagina 116 - 6.1.4 PROFIBUS-DPV1 Mode

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-068.5.11 Χρήση της συσκευής ET 200M / S7-300 σεεπικίνδυνη για έκρηξη περιοχή,

Pagina 117

Technical SpecificationsDistributed I/O Device ET 200MEWA-4NEB780600602-06ΣυντήρησηΓια µια επισκευή πρέπει να σταλθεί το αντίστοιχο δοµικό συγκρότηµα

Pagina 118 - 6.2 Diagnostics Using LEDs

Technical Specifications8-14Distributed I/O Device ET 200MEWA-4NEB780600602-06

Pagina 119

9-1Distributed I/O Device ET 200MEWA-4NEB780600602-06Compatibility Between the IM 153-xModulesIn This Chapter... You can find all the important inform

Pagina 120 -  Check that the bus

Compatibility Between the IM 153-x Modules9-2Distributed I/O Device ET 200MEWA-4NEB780600602-069.1 Compatibility Between the Versions of the IM 153 an

Pagina 121 - Slave Diagnostics

Compatibility Between the IM 153-x Modules9-3Distributed I/O Device ET 200MEWA-4NEB780600602-06Response to the Removal/Insertion InterruptUp to153-1AA

Pagina 122 - STEP 7 User Program

Compatibility Between the IM 153-x Modules9-4Distributed I/O Device ET 200MEWA-4NEB780600602-06Configuration of the IM 153-1 with the General Identifi

Pagina 123 - STEP 5 User Program

Compatibility Between the IM 153-x Modules9-5Distributed I/O Device ET 200MEWA-4NEB780600602-069.2 Compatibility Between the Versions of the IM 153-2/

Pagina 124

Product Overview1-7Distributed I/O Device ET 200MEWA-4NEB780600602-06Table 1-1 Components of an ET 200M, continuedComponent DrawingFunctionSignal modu

Pagina 125 - With IM 153-2Bx00

Compatibility Between the IM 153-x Modules9-6Distributed I/O Device ET 200MEWA-4NEB780600602-06UpgradingYou can upgrade the IM 153-2 (order number 6ES

Pagina 126

Compatibility Between the IM 153-x Modules9-7Distributed I/O Device ET 200MEWA-4NEB780600602-06Configuration of the IM 153-2 with the General Identifi

Pagina 127 - 6.4.2 Station Statuses 1 to 3

Compatibility Between the IM 153-x Modules9-8Distributed I/O Device ET 200MEWA-4NEB780600602-069.3 RC Network with 1 MW for a Configuration withUngrou

Pagina 128 - Station status 3

A-1Distributed I/O Device ET 200MEWA-4NEB780600602-06Order Numbers for the ET 200MComponents for the ET 200MTable A-1 Components for the ET 200M Acces

Pagina 129 - 6.4.4 Manufacturer ID

Order Numbers for the ET 200MA-2Distributed I/O Device ET 200MEWA-4NEB780600602-06Table A-1 Components for the ET 200M, continuedAccessories and Spare

Pagina 130 - 6.4.5 Module Diagnosis

Order Numbers for the ET 200MA-3Distributed I/O Device ET 200MEWA-4NEB780600602-06Table A-2 STEP 7 and SIMATIC S7 ManualsManual ContentsCommunication

Pagina 131 - 6.4.6 Module Status

Order Numbers for the ET 200MA-4Distributed I/O Device ET 200MEWA-4NEB780600602-06BooksTable A-4 Technical LiteratureTechnical guide ContentsDecentral

Pagina 132 - Channel-Specific Diagnosis

Glossary-1Distributed I/O Device ET 200MEWA-4NEB780600602-06GlossaryAutomation systemAn automation system is a ³ programmable logic controller consist

Pagina 133

GlossaryGlossary-2Distributed I/O Device ET 200MEWA-4NEB780600602-06Chassis groundChassis ground refers to all the interconnected inactive parts of a

Pagina 134

GlossaryGlossary-3Distributed I/O Device ET 200MEWA-4NEB780600602-06Device master fileAll slave-specific characteristics are stored in a device master

Pagina 135

Product Overview1-8Distributed I/O Device ET 200MEWA-4NEB780600602-061.3 IM 153-x: Variants and FeaturesBrief Overview of the Different IM 153-xThe IM

Pagina 136

GlossaryGlossary-4Distributed I/O Device ET 200MEWA-4NEB780600602-06DP slaveA ³ slave run on the PROFIBUS bus system with the PROFIBUS-DP protocoland

Pagina 137 - 6.4.9 Interrupts

GlossaryGlossary-5Distributed I/O Device ET 200MEWA-4NEB780600602-06Functional groundingGrounding which has the sole purpose of safeguarding the inten

Pagina 138 - Diagnostic Interrupt

GlossaryGlossary-6Distributed I/O Device ET 200MEWA-4NEB780600602-06IP20Degree of protection to DIN 40050: Protection against contact with fingers and

Pagina 139 - Interrupts

GlossaryGlossary-7Distributed I/O Device ET 200MEWA-4NEB780600602-06Process interruptA process interrupt is triggered by S7-300 modules with interrupt

Pagina 140

GlossaryGlossary-8Distributed I/O Device ET 200MEWA-4NEB780600602-06PROFIBUS-DPThis is the PROFIBUS bus system with the DP protocol. DP stands fordist

Pagina 141

GlossaryGlossary-9Distributed I/O Device ET 200MEWA-4NEB780600602-06Response monitoringThis is a slave parameter. If a DP slave is not addressed withi

Pagina 142

GlossaryGlossary-10Distributed I/O Device ET 200MEWA-4NEB780600602-06STEP 7Programming language for developing user programs for SIMATIC S7 PLCs.Subst

Pagina 143

GlossaryGlossary-11Distributed I/O Device ET 200MEWA-4NEB780600602-06Time stampingBinary input signals are given a time stamp when they are changed. A

Pagina 144

GlossaryGlossary-12Distributed I/O Device ET 200MEWA-4NEB780600602-06

Pagina 145

Index-1Distributed I/O Device ET 200MEWA-4NEB780600602-06IndexNumbers24 V DC supply, 5-3AActive bus module, 1-6, 4-5Active bus modulesinstalling, 4-14

Pagina 146

Product Overview1-9Distributed I/O Device ET 200MEWA-4NEB780600602-06Table 1-2 IM 153-x: features and variants Functions/Interface Module and Order N

Pagina 147

IndexIndex-2Distributed I/O Device ET 200MEWA-4NEB780600602-06DDevice master file, Glossary-3on the Internet at ..., 1-4Diagnosis, 6-16channel-specifi

Pagina 148

IndexIndex-3Distributed I/O Device ET 200MEWA-4NEB780600602-06General technical specifications. See ModuleSpecifications Reference ManualGround, Gloss

Pagina 149 - Maintenance

IndexIndex-4Distributed I/O Device ET 200MEWA-4NEB780600602-06JJumper, 5-15LLabeling strip, 5-20Laser safety class, 8-6LEDsIM 153-1, 6-10IM 153-2, 6-1

Pagina 150

IndexIndex-5Distributed I/O Device ET 200MEWA-4NEB780600602-06RRadio interference, 5-3Rail, 1-6fixing holes, 4-10for active bus modules, 1-6, 4-8for m

Pagina 151 - 7.2 Replacing the IM 153-1

IndexIndex-6Distributed I/O Device ET 200MEWA-4NEB780600602-06UUL, approval, 8-3Ungrounded, Glossary-11Ungrounded reference potential, 5-9Update, Glos

Pagina 152 - Slot Numbering

s Copyright  Siemens AG 2003 Subject to modifications Siemens Aktiengesellschaft SIMATIC Product Information Edition 11/2003 "Distributed

Pagina 153

Copyright  Siemens AG 2003 All rights reserved Disclaimer of Liability Transmission as well as reproduction of this document, utilization and commu

Pagina 154 - Removing a Module

Product Information for Distributed I/O Device ET 200M, Manual A5E00272208-01 3 1 On Section 1.3 and 9.2 Further information for IQ-Sense As from F

Pagina 155 - In the Case of Redundancy:

Product Information for Distributed I/O Device ET 200M, Manual 4 A5E00272208-01 3 On Section 3.7 Further information on the jitter The maximum ji

Pagina 156 - Operation” Function

Product Information for Distributed I/O Device ET 200M, Manual A5E00272208-01 5 Further information on time calculation The following more precise eq

Pagina 157

Product Overview1-10Distributed I/O Device ET 200MEWA-4NEB780600602-06Front View of IM 153-1 and IM 153-2AA02/-2AB01PROFI-BUS-DPPROFIBUS-DPinterface:9

Pagina 158

Product Information for Distributed I/O Device ET 200M, Manual 6 A5E00272208-01 5 On Section 6.4.7 Information on channel-specific diagnosis Erro

Pagina 159

Product Overview1-11Distributed I/O Device ET 200MEWA-4NEB780600602-06Front View of the IM 153-2Bx00PROFIBUS-DPinterface:9-pin socket or fiber-optic c

Pagina 160

Product Overview1-12Distributed I/O Device ET 200MEWA-4NEB780600602-06

Pagina 161 - 7.6 Replacing the Bus Module

2-1Distributed I/O Device ET 200MEWA-4NEB780600602-06Getting StartedChapter OverviewSection Subject Page2.1 Introduction 2-22.2 Order Numbers for the

Pagina 162 - Position of the Fuses

Getting Started2-2Distributed I/O Device ET 200MEWA-4NEB780600602-062.1 IntroductionIn this chapter the following simple sample configuration will sho

Pagina 163 - Changing Fuses

Getting Started2-3Distributed I/O Device ET 200MEWA-4NEB780600602-062.2 Order Numbers for the Sample ConfigurationQuan-tityArticle Order number(Siemen

Pagina 164 - 7.8 Update of the IM 153-x

iiiDistributed I/O Device ET 200MEWA-4NEB780600602-06PrefacePurpose of the ManualThe information in this manual enables you to operate an IM 153 slave

Pagina 165 - Prerequisites

Getting Started2-4Distributed I/O Device ET 200MEWA-4NEB780600602-062.3 Prerequisites You have set up an S7 station consisting of a power supply modu

Pagina 166 - Sample Configuration

Getting Started2-5Distributed I/O Device ET 200MEWA-4NEB780600602-062.5 WiringRail1. Connect the rail to the protective conductor. An M6 screw is prov

Pagina 167 -  When the update has been

Getting Started2-6Distributed I/O Device ET 200MEWA-4NEB780600602-064. Wire the front connector of the DI in the following way:Terminal 1: L+ of PS; T

Pagina 168 - Update Not Successful

Getting Started2-7Distributed I/O Device ET 200MEWA-4NEB780600602-062.6 Putting Hardware into ServiceStep Activity Result1 Connect the programming dev

Pagina 169 - Technical Specifications

Getting Started2-8Distributed I/O Device ET 200MEWA-4NEB780600602-062.7 Configuration1. Start the SIMATIC Manager and create a new project with a DP m

Pagina 170 - CE Approval

Getting Started2-9Distributed I/O Device ET 200MEWA-4NEB780600602-065. Set the following parameters:– in the DP slave properties dialog box for ET 200

Pagina 171 - HAZ. LOC

Getting Started2-10Distributed I/O Device ET 200MEWA-4NEB780600602-062.8 Integration into the User Program1. Create the user program in the LAD/STL/FB

Pagina 172 - IEC 61131

Getting Started2-11Distributed I/O Device ET 200MEWA-4NEB780600602-062.10 Diagnostics1. If a fault occurs, the OB 82 is started. Evaluate the start in

Pagina 173 - Use in residential areas

Getting Started2-12Distributed I/O Device ET 200MEWA-4NEB780600602-06SM 322: Short Circuit to L+1. Open the front door of the DO module and use a wire

Pagina 174

3-1Distributed I/O Device ET 200MEWA-4NEB780600602-06Configuration Options with the ET 200MThis chapter shows you when to use which IM 153-x for what

Pagina 175 - Parameter Assignment

PrefaceivDistributed I/O Device ET 200MEWA-4NEB780600602-06Changes Since the Previous VersionThe following changes have been made since the previous v

Pagina 176 - Parameters for Time Stamping

Configuration Options with the ET 200M3-2Distributed I/O Device ET 200MEWA-4NEB780600602-063.1 Distributed I/Os with the IM 153-1The IM 153-1 is the s

Pagina 177 - 8.3 Technical Specifications

Configuration Options with the ET 200M3-3Distributed I/O Device ET 200MEWA-4NEB780600602-063.2 Forwarding Parameterization Data from the PG/PC withthe

Pagina 178

Configuration Options with the ET 200M3-4Distributed I/O Device ET 200MEWA-4NEB780600602-063.3 Parameterizable FM in a Configuration with an IM 153-2S

Pagina 179

Configuration Options with the ET 200M3-5Distributed I/O Device ET 200MEWA-4NEB780600602-063.4 Time Stamping with the IM153-2Time stamping with IM 153

Pagina 180 - 8.4 Time Delay of the ET 200M

Configuration Options with the ET 200M3-6Distributed I/O Device ET 200MEWA-4NEB780600602-063.4.1 Time Stamping with 10 ms AccuracyThe time stamping of

Pagina 181

Configuration Options with the ET 200M3-7Distributed I/O Device ET 200MEWA-4NEB780600602-06In the Redundant SystemThe IM 153-2 also supports the time

Pagina 182 - Zulassung

Configuration Options with the ET 200M3-8Distributed I/O Device ET 200MEWA-4NEB780600602-063.4.2 Time Stamping with 3 ms AccuracyPrerequisitesThe foll

Pagina 183 - Besondere Bedingungen

Configuration Options with the ET 200M3-9Distributed I/O Device ET 200MEWA-4NEB780600602-063.5 Redundancy with the IM 153-2You can operate the IM 153-

Pagina 184 - Hazardous Area

Configuration Options with the ET 200M3-10Distributed I/O Device ET 200MEWA-4NEB780600602-06Sample Configuration of a Redundant DP Master System and t

Pagina 185 - List of Approved Modules

Configuration Options with the ET 200M3-11Distributed I/O Device ET 200MEWA-4NEB780600602-06S5-115H/155H as DP MasterIf you use the IM 153-2 on an S5-

Pagina 186 - Homologation

PrefacevDistributed I/O Device ET 200MEWA-4NEB780600602-06Position in the Information LandscapeThis delivery package (order number 6ES7 153-1AA00-8BA0

Pagina 187 - Liste des modules homologués

Configuration Options with the ET 200M3-12Distributed I/O Device ET 200MEWA-4NEB780600602-06Configuration with Device Master FilePrincipleWith the IM

Pagina 188 - Homologación

Configuration Options with the ET 200M3-13Distributed I/O Device ET 200MEWA-4NEB780600602-06Configuration modification procedureReconfiguration is per

Pagina 189 - Condiciones especiales

Configuration Options with the ET 200M3-14Distributed I/O Device ET 200MEWA-4NEB780600602-06AttentionIt is the user’s responsibility to ensure that th

Pagina 190 - Autorizzazione

Configuration Options with the ET 200M3-15Distributed I/O Device ET 200MEWA-4NEB780600602-063.7 Clock SynchronismReproducible response times (i.e. res

Pagina 191 - Elenco delle unità abilitate

Configuration Options with the ET 200M3-16Distributed I/O Device ET 200MEWA-4NEB780600602-06Prerequisites Interface module IM 153-2; Order number 6ES

Pagina 192 - Verdere informatie

Configuration Options with the ET 200M3-17Distributed I/O Device ET 200MEWA-4NEB780600602-06Procedure for Parameterizing Clock Synchronism1. Settings

Pagina 193 - Speciale voorwaarden

Configuration Options with the ET 200M3-18Distributed I/O Device ET 200MEWA-4NEB780600602-062. Settings at the DP master system:”Object Properties” of

Pagina 194 - Godkendelse

Configuration Options with the ET 200M3-19Distributed I/O Device ET 200MEWA-4NEB780600602-063. Settings at the DP slave:”Object Properties” of the DP

Pagina 195 - Særlige betingelser

Configuration Options with the ET 200M3-20Distributed I/O Device ET 200MEWA-4NEB780600602-06Time CalculationOnly the processes in the IM 153-2 interfa

Pagina 196 - Hyväksyntä

Configuration Options with the ET 200M3-21Distributed I/O Device ET 200MEWA-4NEB780600602-06Internal Processes of the IM 153-2K[ms] +ȍ5m+1smkmS1= 1 k1

Pagina 197 - Erityiset vaatimukset

PrefaceviDistributed I/O Device ET 200MEWA-4NEB780600602-06CD-ROMYou can also obtain the complete set of ET 200 documentation on CD-ROM.Order number o

Pagina 198 - Godkännande

Configuration Options with the ET 200M3-22Distributed I/O Device ET 200MEWA-4NEB780600602-063.8 Identification DataIdentification data is information

Pagina 199 - Särskilda villkor

Configuration Options with the ET 200M3-23Distributed I/O Device ET 200MEWA-4NEB780600602-062. The item of identification data assigned to the respect

Pagina 200 - Local de produção

Configuration Options with the ET 200M3-24Distributed I/O Device ET 200MEWA-4NEB780600602-06The identification data is assigned to the indices in the

Pagina 201 - Condições especiais

Configuration Options with the ET 200M3-25Distributed I/O Device ET 200MEWA-4NEB780600602-063.9 Fiber-Optic Network with the IM 153-2 FOIn this sectio

Pagina 202 - Τόπος κατασκευής

Configuration Options with the ET 200M3-26Distributed I/O Device ET 200MEWA-4NEB780600602-063.10 Direct CommunicationAs of STEP 7 V 5.0 you can config

Pagina 203 - Ιδιαίτερες προϋποθέσεις

4-1Distributed I/O Device ET 200MEWA-4NEB780600602-06InstallationIntroductionIn this chapter we will show you how to carry out the mechanical configur

Pagina 204

Installation4-2Distributed I/O Device ET 200MEWA-4NEB780600602-064.1 Mechanical ConfigurationIn This SectionSection Subject Page4.1.1 Horizontal and V

Pagina 205 - Chapter Overview

Installation4-3Distributed I/O Device ET 200MEWA-4NEB780600602-064.1.2 Clearance MeasurementsRulesIf you adhere to the minimum clearance measurements:

Pagina 206 - IM 153-1

Installation4-4Distributed I/O Device ET 200MEWA-4NEB780600602-06Length of the RailsDepending on the ET 200M installation you have, you can use the fo

Pagina 207

Installation4-5Distributed I/O Device ET 200MEWA-4NEB780600602-06Installation in an Intrinsically Safe AreaIf you use the ET 200M in intrinsically saf

Pagina 208

PrefaceviiDistributed I/O Device ET 200MEWA-4NEB780600602-06Training CenterWe offer courses to introduce you to the ET 200 Distributed I/O System and

Pagina 209 -  In the non-redundant system

Installation4-6Distributed I/O Device ET 200MEWA-4NEB780600602-06 Use the rails for ”module change during operation” (only these can take theactive b

Pagina 210 - Upgrading

Installation4-7Distributed I/O Device ET 200MEWA-4NEB780600602-06Installation OptionsYou can install up to 9 active bus modules depending on the lengt

Pagina 211

Installation4-8Distributed I/O Device ET 200MEWA-4NEB780600602-064.2 InstallationThere are two configuration types for the ET 200M: Standard configur

Pagina 212 - Subsequent Versions

Installation4-9Distributed I/O Device ET 200MEWA-4NEB780600602-06Are you Installing a 2-Meter Rail?If not, you can skip this section and read on from

Pagina 213 - Order Numbers for the ET 200M

Installation4-10Distributed I/O Device ET 200MEWA-4NEB780600602-06Dimensioned Drawing for Fixing HolesThe fixing-hole dimensions for the rail are show

Pagina 214

Installation4-11Distributed I/O Device ET 200MEWA-4NEB780600602-06Installing the RailTo install the rail, proceed as follows:1. Choose a position for

Pagina 215

Installation4-12Distributed I/O Device ET 200MEWA-4NEB780600602-064.2.2 Standard Configuration (Installing Modules on the Rail)AccessoriesThe accessor

Pagina 216

Installation4-13Distributed I/O Device ET 200MEWA-4NEB780600602-06Sequence for InstallationThe individual steps to be followed when installing the mod

Pagina 217 - Glossary

Installation4-14Distributed I/O Device ET 200MEWA-4NEB780600602-064.2.3 Configuration with Active Bus Modules (Installing Active BusModules and Module

Pagina 218 - Configuration

Installation4-15Distributed I/O Device ET 200MEWA-4NEB780600602-06Plugging in Output Modules During Operation of an ET 200M Installation!WarningWhen y

Pagina 219 - DP master

PrefaceviiiDistributed I/O Device ET 200MEWA-4NEB780600602-06Service & Support on the InternetIn addition to our range of printed documentation, o

Pagina 220

Installation4-16Distributed I/O Device ET 200MEWA-4NEB780600602-06Applying Slot NumbersFigure 4-7 shows you how to apply the slot numbers. The slot nu

Pagina 221

Installation4-17Distributed I/O Device ET 200MEWA-4NEB780600602-064.3 Connecting the Bus ConnectorThe following bus connectors are available: Up to 1

Pagina 222

Installation4-18Distributed I/O Device ET 200MEWA-4NEB780600602-064.4 Connecting the Fiber-Optic Cable to the IM 153-2 FOAccessories Required: Pack o

Pagina 223 - PROFIBUS address

Installation4-19Distributed I/O Device ET 200MEWA-4NEB780600602-06Reusing Fiber-Optic CablesNoteIf you insert used fiber-optic cables in the plug-in a

Pagina 224 - Reference potential

Installation4-20Distributed I/O Device ET 200MEWA-4NEB780600602-06Bending Radius for the Fiber-Optic CableMake sure when you wire the fiber-optic dupl

Pagina 225

Installation4-21Distributed I/O Device ET 200MEWA-4NEB780600602-06Setting the PROFIBUS AddressSet the PROFIBUS address using a screwdriver and with th

Pagina 226 - Time stamp

Installation4-22Distributed I/O Device ET 200MEWA-4NEB780600602-06

Pagina 227 - Ungrounded

5-1Distributed I/O Device ET 200MEWA-4NEB780600602-06WiringIntroductionIn this chapter we show you how to configure the electrical installation and ho

Pagina 228 - Glossary-12

Wiring5-2Distributed I/O Device ET 200MEWA-4NEB780600602-065.1 Electrical ConfigurationSection Subject Page5.1.1 General Rules and Regulations on Oper

Pagina 229

Wiring5-3Distributed I/O Device ET 200MEWA-4NEB780600602-06Note on Radio InterferenceWhen several electronic components are used within a switch cabin

Pagina 230

ixDistributed I/O Device ET 200MEWA-4NEB780600602-06ContentsPreface1 Product Overview2.1 What Are Distributed I/O Devices? 1-1. . . . . . . . . . . .

Pagina 231

Wiring5-4Distributed I/O Device ET 200MEWA-4NEB780600602-06Protection From External Electrical ExposureThe following table shows you what to remember

Pagina 232

Wiring5-5Distributed I/O Device ET 200MEWA-4NEB780600602-065.1.2 Operating the ET 200M with Process I/O Modules on aGrounded SupplyThis section contai

Pagina 233

Wiring5-6Distributed I/O Device ET 200MEWA-4NEB780600602-06Features of Load Power SuppliesThe load power supply feeds input and output circuits (load

Pagina 234

Wiring5-7Distributed I/O Device ET 200MEWA-4NEB780600602-06ET 200M in the Overall ConfigurationFigure 5-1 shows you the position of the ET 200M in the

Pagina 235 - Product Information

Wiring5-8Distributed I/O Device ET 200MEWA-4NEB780600602-06ET 200M with Load Power Supply from the PS 307Figure 5-2 shows the ET 200M in the overall c

Pagina 236 - A5E00272208-01

Wiring5-9Distributed I/O Device ET 200MEWA-4NEB780600602-065.1.3 Configuring the ET 200M with Ungrounded Reference PotentialWhen the ET 200M is config

Pagina 237 - 2 On Section 3.5

Wiring5-10Distributed I/O Device ET 200MEWA-4NEB780600602-06Filtering the 24V DC SupplyIf you supply the IM 153-x from a battery without grounding the

Pagina 238 - 3 On Section 3.7

Wiring5-11Distributed I/O Device ET 200MEWA-4NEB780600602-06Configuration with Isolated ModulesFigure 5-4 shows the potentials of an ET 200M configura

Pagina 239

Wiring5-12Distributed I/O Device ET 200MEWA-4NEB780600602-065.1.5 Configuring the ET 200M with Non-Isolated ModulesPotentials in a Configuration with

Pagina 240 - 5 On Section 6.4.7

Wiring5-13Distributed I/O Device ET 200MEWA-4NEB780600602-065.2 WiringIn This ChapterSection Subject Page5.2.1 Wiring Rules 5-135.2.2 Wiring the Power

Commenti su questo manuale

Nessun commento