Siemens SINUMERIK 802D sl Manuale dell'Operatore Pagina 214

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 340
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 213
Overview of alarms 06/2009
Cycle alarms
2-214
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Alarm display.
Remedy: Program a technology block.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61203 [Channel %1: ] Block %2: No position cycle
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No positioning cycle was programmed in the machining block.
Alarm triggered by following cycles: E_MANAGE, F_MANAGE.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Program positioning block.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61204 [Channel %1: ] Block %2: Technology cycle unknown
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The specified technology cycle in the machining block is unknown.
Alarm triggered by following cycles: E_MANAGE, F_MANAGE.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Delete and reprogram the technology block.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61205 [Channel %1: ] Block %2: Position cycle unknown
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The specified positioning cycle in the machining block is unknown.
Alarm triggered by following cycles: E_MANAGE, F_MANAGE.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Delete and reprogram the positioning block.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61210 [Channel %1: ] Block %2: Block search element not found
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The element specified for the block search does not exisit.
Alarm triggered by following cycles: E_MANAGE, E_PS_CIR, E_PS_MRX, E_PS_POL, E_PS_SEQ,
E_PS_XYA, F_MANAGE, F_PS_CIR, F_PS_MRX, F_PS_SEQ
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Repeat block search.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
Vedere la pagina 213
1 2 ... 209 210 211 212 213 214 215 216 217 218 219 ... 339 340

Commenti su questo manuale

Nessun commento