Cycle alarms
06/2009 Overview of alarms
2-199
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Interface signals are set.
Alarm display.
Remedy: Parameter SDIR (or SDR in CYCLE840) must be programmed.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61103 [Channel %1: ] Block %2: Number of holes is zero
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No value for the number of holes has been programmed. Alarm triggered by following cycles:
HOLES1, HOLES2.
Remedy: Check parameter NUM.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61104 [Channel %1: ] Block %2: Contour violation of slots
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Incorrect parameterization of the milling pattern in the parameters which define the position of the
slots/elongated holes on the circle and their form. Alarm triggered by following cycles: SLOT1, SLOT2,
LONGHOLE.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61105 [Channel %1: ] Block %2: Milling cutter radius too large
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The diameter of the cutter used is too large for the form to be machined. Alarm triggered by following
cycles: SLOT1, SLOT2, POCKET1 to POCKET4, LONGHOLE, CYCLE90.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Either a tool with a smaller radius has to be used or the contour must be modified.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61106 [Channel %1: ] Block %2: Number of or distance between circular
elements
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Incorrect parameterization of NUM or INDA. The layout of the circle elements within a full circle is not
possible. Alarm triggered by following cycles: HOLES2, LONGHOLE, SLOT1, SLOT2.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Correct parameterization.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program