NCK alarms
06/2009 Overview of alarms
2-19
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
4050 NC code identifier %1 cannot be reconfigured to %2
Parameters: %1 = String: Old identifier
%2 = String: New identifier
Definitions: Renaming of an NC code was not possible for one of the following reasons:
- The old identifier does not exist
- The new identifier lies in another type range.
NC codes/keywords can be reconfigured via machine data as long as the type range is not aban-
doned.
Type 1: "real" G codes: G02, G17, G33, G64, ...
Type 2: named G codes: ASPLINE, BRISK, TRANS, ...
Type 3: settable addresses: X, Y, A1, A2, I, J, K, ALF, MEAS, ...
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
Correct MD10712 $MN_NC_USER_CODE_CONF_NAME_TAB (protection level 1).
The list must be built up as follows:
Even address: Identifier to be modified.
Following odd address: New identifier
e.g.: $MN_NC_USER_CODE_CONF_NAME_TAB [10] = "ROT"
$MN_NC_USER_CODE_CONF_NAME_TAB [11] = " "
clears the ROT function from the control
Program Con-
tinuation:
Switch control OFF - ON.
4060 Standard machine data loaded (%1, %2, %3, %4)
Parameters: %1 = Identifier 1
%2 = Identifier 2
%3 = Identifier 3
%4 = Identifier 4
Definitions: The standard MD were loaded because
- a cold start was requested or
- the MD buffer voltage failed or
- an initialization was requested for loading the standard machine data (MD11200 $MN_INIT_MD).
Reaction: Alarm display.
Remedy: Please inform the authorized personnel/service department. After automatically loading the standard
MDs, the individual MDs must be entered or loaded in the relevant system.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4062 Backup data loaded
Definitions: The user data saved in the flash memory are loaded to the SRAM.
Reaction: Alarm display.
Remedy: Load specific machine data again.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4070 Normalizing machine data has been changed
Definitions: The control uses internal physical units (mm, degrees, s, for paths, velocities, acceleration, etc.). Dur-
ing programming or data storage, some of these values are input and output using different units
(rev./min, m/s2, etc.).
The conversion is carried out with the scaling factors that can be entered (system-spefic MD array
MD10230 $MN_SCALING_FACTORS_USER_DEF USER_DEF[n] (n ... index number 0 - 10), when
the corresponding masking bit is set to "1".
If the masking bit is set to "0" then scaling takes place with the internal standard factors.
The following machine data influence the scaling of other MDs:
MD10220: $MN_SCALING_USER_DEF_MASK
MD10230: $MN_SCALING_FACTORS_USER_DEF