Overview of alarms 06/2009
Cycle alarms
2-202
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Interface signals are set.
Alarm display.
Remedy: Check parameter _LP1 or _LP2.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61117 [Channel %1: ] Block %2: Active tool radius <= 0
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The radius of the acive tool is negative or zero. Alarm triggered by following cycles: CYCLE71,
POCKET3, POCKET4.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Modify radius.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61118 [Channel %1: ] Block %2: Length or width = 0
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The length or width of the milling area is illegal. Alarm triggered by following cycle: CYCLE71.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check parameters _LENG and _WID.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61119 [Channel %1: ] Block %2: Nominal or core diameter programmed
incorrectly
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The nominal or core diameter was incorrectly programmed. Alarm triggered by following cycles:
CYCLE70, E_MI_TR, F_MI_TR.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check thread geometry.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61120 [Channel %1: ] Block %2: Thread type inside / outside not defined
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The thread type (internal/external) was not defined. Alarm triggered by following cycles: CYCLE70.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The internal/external thread type must be entered.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program