Cycle alarms
06/2009 Overview of alarms
2-205
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Definitions: Alarm triggered by following cycle: CYCLE69.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61131 [Channel %1: ] Block %2: parameter _GEO incorrect, _GEO=%4
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycle: CYCLE69.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61132 [Channel %1: ] Block %2: parallel axis parameter incorrect, check values
for parallel axis parameters ABS/INK
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycle: CYCLE69.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61133 [Channel %1: ] Block %2: 3rd parallel axis parameter incorrect, check
axis name or GUD _SCW_N[]
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycle: CYCLE69.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61134 [Channel %1: ] Block %2: rotary axis parameter incorrect, check values
for rotary axis parameters ABS/INK
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycle: CYCLE69.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Vedere la pagina 204