Description of the DP Functions, Data, and Error Codes
DP Base Programming Interface for CP 5613/CP 5614
C79000-G8976-C108-01
119
Standard DP Functions
Name Purpose
DPS_get_baud_rate
This function queries the current data transmission
rate.
DPS_get_gc_
command
This function queries the last received global control
command.
DPS_get_state This function queries the current slave state.
DPS_set_diag This function sets new diagnostic data.
DPS_get_ind Receive asynchronous events.
DPS_set_resp Confirm asynchronous events.
DPS_calc_io_data_len Calculate I/O data length based on the configuration
data.