K44 Duo Technical manual 23
Delay on/off
When this function is activated, the following
happens: If a code is programmed to open two
doors, lock relay 2 is not activated until door 1
has been opened and closed.
If door 2 is opened with the exit button, door 2
has to be opened and closed before door 1 can
be opened.
Note that door contacts must be connected and
that Door control must be activated for this to
work.
This is how to activate Delay:
1 Press B and enter the password.
2 Enter A80.
3 Enter 1.
4 Press B to leave programming mode.
To deactivate Delay, press 0 in step 3 instead.