AC75 Hardware Interface Description
Strictly confidential / Preliminary
s
AC75_HD_V00.202 Page 16 of 120 27.04.2006
2 Product Concept
2.1 Key Features at a Glance
Feature Implementation
General
Frequency bands Quad band: GSM 850/900/1800/1900MHz
GSM class Small MS
Output power
(according to
Release 99, V5)
Class 4 (+33dBm ±2dB) for EGSM850
Class 4 (+33dBm ±2dB) for EGSM900
Class 1 (+30dBm ±2dB) for GSM1800
Class 1 (+30dBm ±2dB) for GSM1900
Class E2 (+27dBm ± 3dB) for GSM 850 8-PSK
Class E2 (+27dBm ± 3dB) for GSM 900 8-PSK
Class E2 (+26dBm +3 /-4dB) for GSM 1800 8-PSK
Class E2 (+26dBm +3 /-4dB) for GSM 1900 8-PSK
The values stated above are maximum limits. According to
Release 99, Version 5, the maximum output power in a multislot
configuration may be lower. The nominal reduction of maximum
output power varies with the number of uplink timeslots used and
amounts to 3.0dB for 2Tx, 4.8dB for 3Tx and 6.0dB for 4Tx.
Power supply 3.3V to 4.5V
Ambient operating
temperature according
to IEC 60068-2
Normal operation -30°C to +75°C
Restricted operation -30°C / +85°C
Physical Dimensions: 33.9mm x 55mm x max. 4mm
Weight: approx. 8.5g
RoHS All hardware components fully compliant with EU RoHS Directive
GSM / GPRS / EGPRS features
Data transfer GPRS
Multislot Class 12
Full PBCCH support
Mobile Station Class B
Coding Scheme 1 – 4
EGPRS
Multislot Class 10
Mobile Station Class B
Modulation and Coding Scheme MCS 1 – 9
CSD
V.110, RLP, non-transparent
2.4, 4.8, 9.6, 14.4kbps
USSD
PPP-stack for GPRS data transfer