16 Fiber Optic Ethernet Port Specifications
Section 4.3
Fiber Optic Ethernet Port Specifications
The following details the specifications for fiber optic Ethernet ports that can be ordered with the RS8000.
Mode
e
Connector
Type
Cable
Type (μm)
Tx λ (typ.)
(nm)
Tx min.
(dBm)
Tx max.
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.) (km)
Power
Budget
(dB)
MM MTRJ 50/125 1310 -16 -11 -33.5 -11 2 17
SM LC 9/125 1310 -15 -8 -31 -5 15 16.5
e
MM = Multi-Mode, SM = Single-Mode
Section 4.4
Operating Environment
Parameter Range Comments
Ambient Operating Temperature -40 to 85°C Ambient Temperature as measured from a
30 cm radius surrounding the center of the
enclosure.
Ambient Relative Humidity 5% to 95% Non-condensing
Ambient Storage Temperature -40 to 85°C
Section 4.5
Mechanical Specifications
Parameter Value
Dimensions Refer to Chapter 5, Dimension Drawings
Weight 2.25 kg (5 lbs)
Ingress Protection IP40 (1 mm or 0.04 in objects)
Enclosure 18 AWG Galvanized Steel