Siemens Simatic M7-400 Manuale Utente Pagina 554

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 638
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 553
Interface Submodules
13-58
S7-400, M7-400 Programmable Controllers Module Specifications
A5E00069467-07
Interrupts
The IF 961-CT1 can initiate an interrupt when comparison values are reached or in
the event of overflow, underflow, or zero pass of the counter.
Diagnostic Interrupt
The IF 961-CT1 can initiate a diagnostic interrupt for the following events:
Missing or incorrect counter module parameters
Hardware interrupt lost
Signal A, B, or N faulty
Which Signals Can the IF 961-CT1 Count?
The IF 961-CT1 interface submodule can count signals generated by incremental
encoders with 5 V differential signals or with 24 V signals.
The IF 961-CT1 interface submodule can also count 24 V signals generated, for
example, by a light barrier.
Additional Information
You will find more information about the interface submodule IF 961-CT1 in /108/,
IF 961-CT1 Counter Function Module, Programming and Parameter Assignment
Manual.
Vedere la pagina 553
1 2 ... 549 550 551 552 553 554 555 556 557 558 559 ... 637 638

Commenti su questo manuale

Nessun commento