INSTALLATION
2-11
2.5.5 TEST: Loopback diagnostic functions
Below are functional descriptions for all available loopback objects in
‘TEST’ group. Refer to table 2-4 for all available options.
Configurable objects:
Data Loop: Loopback digital data path within framer in the direction
toward TDM bus.
Transceiver end Framer end
TDM busE1
Loopback path
Figure 2-3 Local Data Loopback path
Remote DL: Loopback digital data path within framer in the direction
toward E1 interface.
Transceiver end Framer end
TDM busE1
Loopback path
Figure 2-4 Remote Data Loopback path