Description
3.2 LED display
SCALANCE W760/W720
12 Operating Instructions, 03/2015, C79000-G8976-C322-04
3.2
LED display
Information on operating status and data transfer
On the front of the housing, several LEDs provide information on the operating status of the
device:
LED
Color
Meaning
L1
Green
Power supply L1.
P1
Green
There is a connection via the Ethernet interface (Link).
Green and yellow
flashing alternately
Data transfer via the Ethernet interface.
R1 Green
SCALANCE W760 in access point mode:
The WLAN interface is initialized and ready for operation.
SCALANCE W760 in client mode or SCALANCE W720:
There is a connection via the WLAN interface.
Green and yellow
flashing alternately
Data transfer over the WLAN interface.
Green
flashing briefly
SCALANCE W760 in access point mode:
With 802.11h, the channel is scanned for one minute for primary users
before the channel can be used for data traffic.
SCALANCE W760 in client mode or SCALANCE W720:
The client waits for the MAC address due to the setting "Automatic" for
the "MAC mode" parameter and is connected to no access point.
Green
flashing 3 x short, 1
x long
SCALANCE W760 in client mode or SCALANCE W720:
The client waits for the MAC address due to the setting "Automatic" for
the "MAC mode" parameter and is connected to an access point.