9. Maintenance
9.1 Maintenance of the Limit Switch on X Axis
9.1.1 Select the MPG mode and X axis which on the control panel.
9.1.2 Adjust the X axis home position.
Move the X axis toward to positive direction until the limit
switch touch inside the home dog of the X axis 9-10mm, as
shown in the below drawing. Now the 0 series diagnosis No.
16 bit 5(18 series:X1009 bit 0) interchange 1 into 0. If it
doesn’t interchange to 0, please adjust the switch till touch
the home dog and the number is changed to 0.
9.1.3 Move the X axis continuously and toward to positive
direction when the 0 series diagnosis number 16 bit 5(18
series:X1009 bit 0) display 0. Then, move again the X axis
until the 0 series diagnosis No. 16 bit 5(18 series:X1009 bit 0)
change 0 into 1. Now the limit switch to away and not touch
the home dog.
9.1.4 Please move X axis again. When the limit switch touch the
emergency dog, the 0 series diagnosis No. 21 bit 4(18
series:X1008 bit 0) change 1 into 0 and jump to
MDI
mode
on control panel. The screen will display “
NOT READY
message.
9.1.5 Press the
EMG.
release button. Now, move the X axis toward
to negative direction and the limit switch go away the dog.
Check the 0 series diagnosis No. 16 bit 5 (18 series:X1009 bit
0) and 0 series 21 bit 4(18 series:X1008 bit 0) to display 1.