Siemens SIMATIC TI505 Specifiche
Navigare online o scaricare Specifiche per Gateway/Controller Siemens SIMATIC TI505. Siemens SIMATIC TI505 Specifications Manuale Utente
File PDF · ·
Sommario
Simatic/TI 505 Serial Driver Help © 2012 Kepware Technologies
Table of Contents 2 Simatic/TI 505 Serial Driver Help 3 Overview 3 Device Setup 4 Modem Setup 4 Addressing Options 4 Data Types Description 6 Address…
Help version 1.019 CONTENTS Overview What is the Simatic/TI 505 Serial Driver? Device Setup How do I configure a device for use with this driver? Data…
Device Setup Supported Devices TI Series 500/505 processors: 520, 525, 535, 545, 555, 565 and 575. Communication Protocol Non-Intelligent Terminal…
Memory types that allow bit within Word (for example, V) can be referenced as a Boolean. The addressing notation for doing this is as follows: <memory…
Data Types Description Data Type Description Boolean Single bit Word Unsigned 16 bit value bit 0 is the low bit bit 15 is the high bit Short Signed 16…
Address Descriptions Address specifications vary depending on the model in use. Select a link from the following list to obtain specific address…
Transparent Byte Addressing The Simatic/TI 505 Serial driver supports the following addresses when using the Tranparent Byte protocol. The default…
Register Description CP525 CP545 CP565 CTI 2500 STW00001 Non-Fatal Errors. Bit 4, 1 = Password has been entered. Bit 5, 1 = Password has been entered…
DP Slave channels if present. STW027 is slave 1…STW138 is slave 112. Bit range is the same as for STW011. STW00139 This Status Word provides a count…
Bit 13, 1 = Attempt to invoke restricted special function program or subroutine. STW00163 Contains the number of the ladder subroutine that caused the…
Bit 3, 1 = First Run Mode scan after transition from Hold Mode. Bit 9, 1 = First scan after battery bad power-up restart. Bit 10, 1 = First scan after…
STW0231 Profibus DP I/O Status. Bit 1, 1 = DP in operate state. Bit 2, 1 = DP in clear state. Bit 3, 1 = Error: Unable to download configuration to…
stopped communicating with the remote base due to communications errors or response timeouts. STW 471 corresponds to remote base 1. STW 472 – STW 485…
Error Descriptions The following error/warning messages may be generated. Click on the link for a description of the message. Address Validation…
Solution: Re-enter the address in the client application. Address '<address>' is out of range for the specified device or register Error Type: Warning…
Serial Communications COMn does not exist Error opening COMn COMn is in use by another application Unable to set comm parameters on COMn…
T = TX buffer full. Possible Cause: 1. The serial connection between the device and the host PC is bad. 2. The communications parameters for the…
The location is read only in the device. 3. The device could not perform the write operation. Solution: Refer to the list of error codes. See Also…
Index A Address Descriptions 7 Address Validation 15 Addressing Options 4 Array size is out of range for address '<address>' 16 Array support is not…
Framing 17 L Long 6 M Mask 17 Missing address 15 Modem Setup 4 N Network 4 NITP Addressing 7 O Overrun 17 Overview 3 P Parity 17 S Serial…
U Unable to read block starting at <address> for device <device name>:Error code <code> 19 Unable to set comm parameters on COMn 17 Unable to write…
Più documenti per Gateway/Controller Siemens SIMATIC TI505
Siemens SIMATIC TI505 Manuale di Servizio
(53 pagine)
Siemens SIMATIC TI505 Manuale Utente
(91 pagine)
Siemens SIMATIC TI505 Manuale di Servizio
(127 pagine)
Siemens SIMATIC TI505 Guida Utente
(39 pagine)
Domande su Siemens SIMATIC TI505
Non ci sono ancora domande su questo manuale. Fate la prima.
Prodotti e manuali riguardanti Gateway/Controller Siemens SIMATIC TI505
- Gateway/Controller Siemens 5935 Specifiche
(174 pagine) - Gateway/Controller Siemens NK8225 Manuale Utente
(22 pagine) - Gateway/Controller Siemens SIMATIC TI505 Manuale di Servizio
(53 pagine) - Gateway/Controller Siemens SIMATIC TI505 Manuale di Servizio
(127 pagine) - Gateway/Controller Siemens SIMATIC TI500 Manuale Utente
(94 pagine) - Gateway/Controller Siemens Advance Network Gateway Manuale Utente
(88 pagine) - Gateway/Controller Siemens Advance Network Gateway Manuale Utente
(72 pagine) - Gateway/Controller Siemens 5930 Specifiche
(56 pagine) - Gateway/Controller Siemens 5930 Manuale Utente
(20 pagine) - Gateway/Controller Siemens SIMATIC TI500 Specifiche
(322 pagine) - Gateway/Controller Siemens 5930 Guida Utente
(94 pagine) - Gateway/Controller Siemens 5930 Manuale Utente
(4 pagine) - Gateway/Controller Siemens Advance Network Gateway Manuale Utente
(95 pagine) - Gateway/Controller Siemens 2602 Guida Utente
(32 pagine) - Gateway/Controller Siemens SIMATIC TI505 Manuale Utente
(91 pagine)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22