Siemens SIMATIC TI505 Specifiche

Navigare online o scaricare Specifiche per Gateway/Controller Siemens SIMATIC TI505. Siemens SIMATIC TI505 Specifications Manuale Utente

Simatic/TI 505 Serial
Driver Help
© 2012 Kepware Technologies

File PDF · ·

Stampa

Stampa documento

Condivisione

Sommario

Pagina 1 - Driver Help

Simatic/TI 505 Serial Driver Help © 2012 Kepware Technologies

Pagina 2 - Table of Contents

Table of Contents 2 Simatic/TI 505 Serial Driver Help 3 Overview 3 Device Setup 4 Modem Setup 4 Addressing Options 4 Data Types Description 6 Address…

Pagina 3 - Overview

Help version 1.019 CONTENTS Overview What is the Simatic/TI 505 Serial Driver? Device Setup How do I configure a device for use with this driver? Data…

Pagina 4 - Addressing Options

Device Setup Supported Devices TI Series 500/505 processors: 520, 525, 535, 545, 555, 565 and 575. Communication Protocol Non-Intelligent Terminal…

Pagina 5 - Bit Order for V, K, STW

Memory types that allow bit within Word (for example, V) can be referenced as a Boolean. The addressing notation for doing this is as follows: <memory…

Pagina 6 - Data Types Description

Data Types Description Data Type Description Boolean Single bit Word Unsigned 16 bit value bit 0 is the low bit bit 15 is the high bit Short Signed 16…

Pagina 7 - NITP Addressing

Address Descriptions Address specifications vary depending on the model in use. Select a link from the following list to obtain specific address…

Pagina 8 - Status Words

Transparent Byte Addressing The Simatic/TI 505 Serial driver supports the following addresses when using the Tranparent Byte protocol. The default…

Pagina 9

Register Description CP525 CP545 CP565 CTI 2500 STW00001 Non-Fatal Errors. Bit 4, 1 = Password has been entered. Bit 5, 1 = Password has been entered…

Pagina 10

DP Slave channels if present. STW027 is slave 1…STW138 is slave 112. Bit range is the same as for STW011. STW00139 This Status Word provides a count…

Pagina 11

Bit 13, 1 = Attempt to invoke restricted special function program or subroutine. STW00163 Contains the number of the ladder subroutine that caused the…

Pagina 12

Bit 3, 1 = First Run Mode scan after transition from Hold Mode. Bit 9, 1 = First scan after battery bad power-up restart. Bit 10, 1 = First scan after…

Pagina 13

STW0231 Profibus DP I/O Status. Bit 1, 1 = DP in operate state. Bit 2, 1 = DP in clear state. Bit 3, 1 = Error: Unable to download configuration to…

Pagina 14

stopped communicating with the remote base due to communications errors or response timeouts. STW 471 corresponds to remote base 1. STW 472 – STW 485…

Pagina 15

Error Descriptions The following error/warning messages may be generated. Click on the link for a description of the message. Address Validation…

Pagina 16

Solution: Re-enter the address in the client application. Address '<address>' is out of range for the specified device or register Error Type: Warning…

Pagina 17

Serial Communications COMn does not exist Error opening COMn COMn is in use by another application Unable to set comm parameters on COMn…

Pagina 18

T = TX buffer full. Possible Cause: 1. The serial connection between the device and the host PC is bad. 2. The communications parameters for the…

Pagina 19

The location is read only in the device. 3. The device could not perform the write operation. Solution: Refer to the list of error codes. See Also…

Pagina 20

Index A Address Descriptions 7 Address Validation 15 Addressing Options 4 Array size is out of range for address '<address>' 16 Array support is not…

Pagina 21

Framing 17 L Long 6 M Mask 17 Missing address 15 Modem Setup 4 N Network 4 NITP Addressing 7 O Overrun 17 Overview 3 P Parity 17 S Serial…

Pagina 22

U Unable to read block starting at <address> for device <device name>:Error code <code> 19 Unable to set comm parameters on COMn 17 Unable to write…

Più documenti per Gateway/Controller Siemens SIMATIC TI505

Domande su Siemens SIMATIC TI505

Non ci sono ancora domande su questo manuale. Fate la prima.

Fai una domanda

Rispondiamo in base al manuale e indichiamo la pagina. La domanda viene pubblicata sul sito dopo il controllo.

Tutte le domande e risposte ›

Prodotti e manuali riguardanti Gateway/Controller Siemens SIMATIC TI505